Process water
Crushing and wash water carry solids and hardness.
Company
About usDealershipCertificatesReferencesBlogSearch the siteContact
+90 (216) 573 4014[email protected]
At a mine, water cools the equipment and moves through the process. Dust, hardness and reuse concentrate the water fast.
Scale in a cooling tower · Corrosion in a closed loop · Scale and fouling on the membrane · What is an antiscalant
Crushing and wash water carry solids and hardness.
Evaporation raises hardness. Dust sticks to the fill.
Closed cooling of heavy equipment replaces little water. Corrosion and sludge block the passage.
Returned water is saltier. If a membrane is used, saturation rises.
Suspended sludge sticks to the hot surface and to the fill.
Hard water speeds scale in the tower and in the exchanger.
If cooling stops, the machine overheats and stops.
If the water analysis is late, scale and corrosion grow before they are seen. Set the program for the site conditions.
The scale chemical and the dispersant work together. Sludge does not leave with a scale inhibitor alone.
Put a corrosion inhibitor in the equipment circuit. Flush brown water first.
Read the hardness of the feed water and the tower water on a regular schedule. Open blowdown from this data.
If reverse osmosis is used, select the antiscalant from the projection report. High hardness needs the more concentrated product.
The tower chemical, the dispersant, the closed loop and the antiscalant are separate jobs. The dosage is set from the water analysis. NSF approval applies only to C scalant 2005.
Stabilized Phosphate Cooling Water Treatment Chemical
It decreases the risk of scaling and corrosion in cooling towers.
Cooling Water Dispersant
It is a dispersant for cooling towers. It prevents suspended particles and sludge from sticking to the surface.
Nitrite-Based Corrosion Inhibitor for Closed-Loop Heating and Cooling Systems – Copper Protection
It protects copper surfaces against corrosion in closed-loop heating and cooling.
NSF-approved antiscalant for drinking water
It is a high-concentration antiscalant. It also protects the reverse osmosis membrane at high hardness. The product is NSF approved.

Cemkimsan makes the chemical in its own plant and ships it to the site. The mine program is set from the water analysis.
Ck 220 decreases the scale and corrosion risk. Ck 180 prevents suspended particles and sludge from sticking to the surface. The dispersant is necessary for sludge. Set blowdown from conductivity and hardness.
Ck 13 protects the copper surface in closed-loop heating and cooling. If the water turns brown, remove the collected dirt first.
At high hardness, C scalant 2005 protects the membrane. The product is NSF approved and high concentration. The dosage is set from the projection report.
Dust and hardness change from site to site. The same dose does not fit every water. If the analysis is late, scale grows before it is seen.
Send the tower water analysis and the reuse water analysis. Our technical team will reply on the tower, the dispersant and the antiscalant.
We reply to quote requests within 12 hours.