Water Treatment in a Hotel

In a hotel, water carries guest comfort and the steam for the kitchen and the laundry. The tower and the hot water carry a hygiene risk. The closed loop and the boiler are watched separately.

Scale in a cooling tower · Corrosion in a closed loop · Scale in a steam boiler

Where the water is used

Cooling tower

The air-conditioning load goes to an open tower. Evaporation raises hardness. Air and sun grow biofilm.

Hot water

The guest waits for hot water. A low temperature and a stagnant line hold biofilm.

Chiller and closed loop

Closed heating and cooling water is replaced rarely. Oxygen and sludge attack the metal.

Laundry and kitchen

The steam boiler serves the laundry and the kitchen. Scale raises fuel use.

Risks specific to this sector

Legionella

An open tower and the hot water can grow a Legionella risk if they hold biofilm. C biocide 886 lowers that risk in open cooling.

Guest comfort

If the chiller cannot cool, the room temperature rises. Scale and sludge close the exchanger.

Closed-loop heating

Heating water that is replaced rarely goes to corrosion and sludge. A radiator does not heat in one area.

Kitchen and laundry steam

If steam stops, the kitchen and the laundry stop. Boiler scale burns more fuel for the same load.

What damage does it cause?

A complaint

A hot room or cold water disturbs the guest.

Hygiene risk

An untreated tower and untreated hot water hold biofilm.

Energy use rises

A scaled boiler and a blocked exchanger run longer.

An unplanned stop

A failure cuts the laundry, the kitchen or the air conditioning.

Signs

  • Algae, foam or a slimy deposit is visible on the tower.
  • The room does not cool enough, or a fan coil works only in one area.
  • Closed-loop water turns brown, or pump noise rises.
  • The laundry needs more steam or more fuel for the same load.

How do you solve it?

Tower biocide

C biocide 886 is put in the program for biofilm in open cooling. Scale needs a separate tower chemical.

Hot-water checks

Check the hot-water temperature and the end point on a regular schedule. Flush a stagnant line.

Closed loop

Put a corrosion inhibitor in the heating circuit. If there is a freeze risk, select the antifreeze separately.

Steam boiler

Treat the laundry and kitchen boiler from the feed water analysis.

Our related products

The tower, the closed loop and the steam boiler are separate jobs. NSF approval applies only to Cefopol 1040, Cemolin 1080 and Ck 229. The dosage is set from the water analysis.

Ck 220

Stabilized Phosphate Cooling Water Treatment Chemical

It decreases the risk of scaling and corrosion in cooling towers.

NSF approved

Ck 229

Stabilized Phosphate Cooling Water Treatment Chemical – For Copper (NSF APPROVED)

It is an NSF approved cooling-water chemical for copper. It prevents scale and corrosion.

Ck 13

Nitrite-Based Corrosion Inhibitor for Closed-Loop Heating and Cooling Systems – Copper Protection

It protects copper surfaces against corrosion in closed-loop heating and cooling.

NSF approved

Cefopol 1040

Multifunctional Steam Boiler Scale and Corrosion Inhibitor – NSF Approved

It is an NSF approved boiler chemical. It prevents scaling and protects the metal against corrosion.

NSF approved

Cemolin 1080

Steam Line Corrosion Inhibitor – NSF approved

It is an NSF approved steam-line inhibitor. It decreases the corrosion risk in the line.

The Cemkimsan team in front of a container loaded with chemical drums.

Why Cemkimsan?

Cemkimsan makes the chemical in its own plant and ships it. The hotel program is set from the tower water analysis and the boiler water analysis.

Frequently asked questions

How do you lower the Legionella risk in a hotel cooling tower?

C biocide 886 prevents biofilm in open cooling and lowers the Legionella risk. Ck 220 is also used for scale. The application frequency is set from the biological load in the tower.

Where do you look if a guest floor does not cool?

Check the chiller and the closed-loop water. Scale and sludge can close the exchanger. Ck 13 protects the copper surface in the closed loop.

Which product do you select for the laundry boiler?

Cefopol 1040 prevents scale and corrosion in the boiler water. Cemolin 1080 lowers the corrosion risk in the steam line. Both are NSF approved. The choice depends on the feed water analysis.

Why is the hot-water line watched separately?

A stagnant, warm line holds biofilm. Read the temperature and the end point on a regular schedule. This job does not replace the tower biocide.

We read your hotel tower water and boiler water with you

Send your tower water analysis and your hot-water routine. Our technical team will reply on the biocide, the tower and the boiler.

We reply to quote requests within 12 hours.